Unit Display Panel
Live Circuit Status
Phoenix Phase Converters · GP20/40NL · AutoStart
IDLER
MOTOR
MOTOR
ON
OFF
LOAD
ON
OFF
START
CIRCUIT
CIRCUIT
ON
OFF
Start circuit disengages automatically after motor reaches speed
Generated 3rd Phase Voltage
218
V
● Normal
Temperature Monitoring
Idler Motor
● Normal
Start Capacitors
● Normal
● <160°F Normal
● 160–185°F Warning
● >185°F Shutdown
Contactor Health
Start Contactor (K1)
Controls start capacitor bank · Aux contact monitored
✓ Normal
Run Contactor (K2)
Main run circuit · Aux contact monitored
✓ Normal
Monitoring Subscription
Free Trial
30-Day Free Trial
Full access to all remote monitoring features
⏳ Trial expires June 20, 2026 — subscribe to keep access
Day 7 of 30
23 days remaining
Maintenance Schedule
2 Due
Timing Sequence Adjustments
🔓 Service Mode
⚠️ These settings affect how your phase converter starts and protects itself. Only adjust if instructed by Phoenix Phase Converters support.
Startup Protection Delay
Seconds after start before voltage protection activates (default: 20s)
20s
Start Capacitor Engagement Time
How long K1 stays closed during start sequence (default: 3s)
3.0s
K1 → K2 Run Transition Delay
Pause between start cap dropout and run contactor closure (default: 0.5s)
0.5s
Pre-Start Buzzer Countdown
Warning countdown before remote or timer start (default: 10s)
10s
Recent Activity
Unit came online — AutoStart triggered normally
Today, 7:02 AM
Unit shut down — normal end of day cycle
Yesterday, 5:48 PM
Remote diagnostic completed — all systems normal
May 18, 2:15 PM
Unit installed and commissioned — Harrington Welding
January 14, 2024
Manual Control
Override AutoStart
Voltage Protection Settings
⬇ Low Voltage Shutdown
Unit shuts down if generated voltage drops below this
195V
⚠ High Voltage Warning
Alerts customer — unit still running above this level
250V
⬆ High Voltage Shutdown
Unit shuts down if generated voltage exceeds this (after 20s startup)
260V
Schedule Timer
Auto Start & Stop